Power Conditioner Furman CN-3600SE merupakan power conditioner dengan kelas professional. Dirancang sesuai dengan standar eropa sehingga memungkinkan pemakaian sangat hemat energi & tidak mudah konslet dalam penggunaan alat sound system anda.
Specifications :
AC Voltage Input Range
Maximum AC Current Rating
- 16 amps (Thermal breaker)
AC Cord
- 1.5mm2x3, 2.5m Long, black, IEC C19 Female to Schuko CEE 7/7 Male Plug
AC Receptacles
- Rear Panel Outlets: 1 IEC C13 pair (Unswitched), 3 IEC C13 pairs (Sequenced, each pair is controlled by separate relay)
- Front Panel: 1 IEC C13 (Unswitched)
Surge/Under-Overvoltage Protection
- AC Surge Protection: Series Multi-Stage Protection SMP
- Spike Protection Mode: Line to neutral, zero ground leakage
- Spike Clamping Voltage: 375V peak @ 6,000 volts/3,000 amps
- Response Time: 1 nanosecond
- Maximum Surge Current: 6,500 Amps
- AC Undervoltage Protection: EVS, 175VAC+/-3VAC
- AC Overvoltage Protection: EVS, 275VAC+/-5VAC
- AC Overvoltage Reset Modes: Manual and Auto-reset (configurable)
AC Filtering
- LiFT
- Noise Attenuation: Linear, 10dB @10KHz, 40dB@100KHz, 50dB@500KHz
Operating Temperature Range
- 5C (40F) to 40C (105F) degrees
Humidity Range
- <90% rH (Relative Humidity)
User Interface
- Keyswitch: Front panel, 3-position keyswitch (On, Off, Remote)
- Keys: Included, 1 pair
- Pushbutton Switch: Front panel, hidden by security cover
- Circuit Breaker: Front panel, pushbutton, 20A Thermal Breaker
- Front panel diagnostic indicators: Primary link, Secondary link, Ethernet, Remote off, Delay 1, Delay 2, Delay 3, Power, Protection OK, Extreme Voltage
- Front Panel DIP Switches: Front panel. Hidden by security cover, 1 Minute Delay, 2 Minute Delay, 4 Minute Delay, Force Off NO/NC, 12V Mode On/Off BND Mode On, Momentary/Maintained, Primary/Secondary, EVS Reset Auto/Manual
- Potentiometer: Front panel, hidden by security cover, fine tune delay adjust
Control/Status/Triggering (Rear Panel):
- Remote Terminal: +5-30VDC In, 12VDC (12mA) Out
- SmartSequencing: Phoenix 4-Pin Connector, Screw Terminals, Primary & Secondary Links (Current Loop - 1000’ nominal)
- Remote Terminal: Phoenix 4-Pin Connector With Screw Terminals; +12V, STAT, REM, GND (Class 2 Wiring)
- Force Off/Delay 3 Terminal: Phoenix 5-Pin Connector With Screw Terminals, FORCE OFF, DELAY 3 (Class 2 Wiring)
- RS-232 Compatible: Yes, DB-9 Connector
- IP Addressability: Optional, via BB-RS232 Ethernet/RS-232 Adaptor (sold separately) for IP control via Telnet, HTTP, BlueBOLT®
- Voltmeter: Available with RS-232/Ethernet option, ± 2VAC accuracy
- Ammeter: Available with RS-232/Ethernet option, ±1A accuracy
Power Consumption (No Load):